Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. Copy goes here. This is a place for copy. This will be cooler once it's done. For real. 

Exterior dimensions28.75 in x 19.25 in x 18.75 in (73 cm x 49 cm x 48 cm)
Installation space requirement30.75in x 21.25 in x 20.75 in (2 inches on all sides)
Sterilization chamber dimensions*18 in x 16 in x 7 in (46 cm x 41 cm x 18 cm)
Sterilization chamber volume*33 L (8.7 gal)
Sterilization tray dimensions*16 in x 10 in x 4 in (41 cm x 25 cm x 10 cm)
Sterilization tray volume*10.5 L (2.8 gal)
Weight110 lbs (49.9 kg)
Operating temperature0-40 °C (32-104 °F)
Storage temperature0-50 °C (32-122 °F)
Electrical requirements110-120 VAC single phase, 50/60Hz, 6.5 A max

*Instruments being sterilized must fit within the area of the sterilization tray.

V10 Data Sheet

V10 Brochure

Material Compatibility with Air Plasma Sterilization™ Process

Recommended Pouches and Wraps for Air Plasma Sterilization™ Process

ConsumableUsable life (sterilization cycles)DisposalShelf lifeStorage
Plasma sheet15No restrictions*IndefiniteAway from heat and moisture
Desiccant canister50-75No restrictionsIndefinite**Away from heat and moisture
Catalyst canister200No restrictionsIndefinite**Away from heat and moisture
Chemical indicator tapeN/ANo restrictionsIndefiniteAway from heat, moisture, and oxidative gases

*Plasma sheets can be returned to Plasma Bionics LLC for recycling
**Indefinite shelf life in original packaging

Type of sterilization cycleSingle cycle sterilizes most general surgical and laparoscopic instruments*
Sterilization processAir Plasma Sterilization™ process, terminal sterilization using overkill method to provide SAL of 10-6
Total sterilization cycle timeApproximately 4 hours
Preconditioning time15-20 min**
Sterilizing time3 hours
Ventilating time45 minutes
SterilantReactive oxygen and nitrogen species, primarily ozone, nitrogen dioxide, and hydroxyl radicals
Sterilant productionSterilant gases produced from preconditioned air along the surface of the plasma sheet
Sterilant deliverySterilant gases are produced inside the sterilization chamber
Sterilant removalSterilant gases are pumped through Carulite® 200 granular catalyst, converted back into air, and pumped back into the sterilization chamber
Critical process parametersAir temperature, pressure, and humidity are monitored and conditioned during the preconditioning step, voltage feedback from plasma production is monitored throughout the sterilizing step
Sterility assuranceBiological indicators (≥106 spores of Geobacillus stearothermophilus)

*See lumen claims below and separate material compatibility lists
**Preconditioning time may vary based on environmental conditions (i.e. relative humidity, temperature, altitude)

What Our Clients Say

"This is such an easy to use, easy to transport sterilization device! I love that I can sterilize my instruments in my clinic, as well as in my vehicle while traveling to the next client. It’s also a fast and dry solution, making it a must-have for any busy veterinarian."

Dr. Lisa Mauzerall

“This is a convenient, relatively quick method of sterilization. It’s a great way for mobile veterinarians to have the ability to sterilize instruments in the field.”

Dr. Amy Storm

"All the benefits of an autoclave without the hassle. It’s a quick, easy and dry process for all of my instruments. In my opinion, a must have for a mobile veterinarian who needs sterilization on the go."

Dr. Brent Pitts